AoKu ARD Series Elevator Automatic Rescue Device UPS Power (1000VA / 1500VA / 2000VA)
AoKu ARD Series

AoKu ARD Series Elevator Automatic Rescue Device UPS Power (1000VA / 1500VA / 2000VA)

AoKu ARD Series (1000VA - 2000VA) is a specialized Elevator Automatic Rescue Device and pure sine wave UPS. Designed for synchronous and asynchronous VVVF drive lifts, it derives inverter DC bus power directly from 60Vdc (48V/72V/96V/120V optional) battery banks while providing 220Vac control power, <10ms transfer time, selectable K1 delayed output (5s/10s/20s), 5-minute auto shut-off, and non-battery pass-through fail-safe operation.

Capacity 1000VA / 1500VA / 2000VA
Stock Status In Stock

Frequently Asked Questions

What is an Elevator Automatic Rescue Device (ARD) and how does it differ from a standard commercial UPS?
An Elevator ARD is a specialized emergency UPS system specifically engineered for lift evacuation during grid blackouts. Unlike standard UPS units, the AoKu ARD powers the elevator control electronics (220Vac) while deriving power directly from the battery bank to energize the motor inverter DC bus. Crucially, the AoKu ARD features a fail-safe pass-through mechanism: if the batteries are disconnected, faulty, or completely drained, grid AC power still flows directly to the lift controller during normal operation, ensuring the elevator is never taken offline by a battery fault.
Is the AoKu ARD Series compatible with gearless synchronous and geared asynchronous elevator motors?
Yes. The AoKu ARD Series operates seamlessly with both synchronous and asynchronous traction motors and is compatible with all major VVVF elevator drive inverters (e.g., Yaskawa, Monarch, STEP, Fuji, KONE, OTIS, Schindler). Because the inverter's DC bus is powered directly from the ARD battery bank, the system handles emergency rescue across all elevator panel power ratings.
How does the K1 delayed output function work and how do I configure the delay time?
The K1 output is a time-delayed 220Vac line designed to energize specific brake or contactor circuits after the main lift control panel initializes. The delay time can be set to 5 seconds, 10 seconds, or 20 seconds using the jumper header on the control PCB (No. BINV-CON): Jumper pins 13-14 for 5s, pins 5-6 for 10s, and pins 3-4 for 20s.
What happens during an emergency power failure, and why does the ARD shut down after 5 minutes?
When main AC power fails, the ARD instantly switches to battery mode (<10ms transfer time) and supplies pure sine wave power to the control panel and inverter. The elevator moves the cabin to the nearest floor and opens the doors. After 5 minutes, the ARD automatically shuts down completely to enter zero-current standby mode. This prevents deep discharge damage to the battery bank during extended blackouts.
What auxiliary DC outputs and dry contact control terminals are available on the ARD PCB?
The AoKu ARD board includes an optional 12Vdc auxiliary output for elevator emergency intercoms and alarm systems, as well as an optional 310Vdc output for specialized inverter control circuits (such as Yaskawa L1000A CN19). It also features a Dry Connector Board with inputs for Door Limit Switches (to stop emergency operation once doors open) and status signal outputs (C-D and E-F) to notify the elevator controller of power state changes.
What maintenance is required to ensure reliable ARD operation?
To maintain optimal performance, batteries should be checked periodically for terminal voltage (12V-13V under load). The system includes an accessible on-board AC input fuse and battery breaker for easy servicing. For long battery life, ambient machine room temperatures should be kept below 45°C, and a monthly simulated evacuation test during routine lift maintenance is recommended to keep battery cells active.
CTA Background

Global Support & Services

Expert customization and technical assistance for your projects.

Pre-Sales Support

Custom configuration and technical consultation.

Post-Sales Support

24/7 assistance and localized parts support.

Global Warranty

Comprehensive coverage for all our hardware solutions globally.